Please select your country

Please select your language

 
Kobold Messring GmbH > Flow  > Variable Area Flowmeter and -switches > Variable Area Flowmeter/- switch V30

Variable Area Flowmeter/- switch V30

Variable Area Flowmeter/- switch  V30
Measuring -/switching range
10 -100 l/h ... 1.000 - 10.000 L/h water
0,3 - 3 Nl/h ... 30- 300 Nm³/h air
Connection G 1/2... G2 fem, hose connector, glue-in conn.,
flange DN 15..DN50, ANSI 1/2"..2"
Material glass inside protection tube
Max. pressure 15 bar
Max. temperature 0..+80 °C
Accuracy ± 2 % v. FS
Option contact